DATA SHEET

Digital Conductivity/TDS Meter and controller.

 Maintain cycles of concentration of tower water by continuously monitoring the Tower water conductivity.

 Bleed control: Once the programmable Set point value is reached, an output is activated which operates a solenoid valve to bleed the Tower water in order to maintain Setpoint.

Digital LCD display for easy set-up and monitoring – displays measured Conductivity (uS/TDS) as well as uS/TDS Set point

Conductivity range 0 - 10 000µS, resolution is in 1µS increments

Electronic 2 point calibration via keypad(Zero and Slope)

BASIC BLEED CONTROLLER

DATA SHEET

 

Digital Conductivity/TDS Meter and controller.

Maintain cycles of concentration of tower water by continuously monitoring the Tower water’s conductivity.

Bleed control: Once the programmable Setpoint value is reached, an output is activated which operates a solenoid valve to bleed Tower water.

Digital LCD display for easy set-up and monitoring – displays measured Conductivity (uS/TDS) the uS/TDS Setpoint and the measured temperature of the cooling tower water

Conductivity range 0 - 10 000µS, resolution is in 1µS increments

Failsafe High, Low TDS/Conductivity and Bleed Timer alarms

Electronic 2 point calibration via keypad(Zero and Slope)

 

Ordering Options:

Data logging and real time clock calendar

Remote connectivity via cellular engine

4-20mA and BMS retransmission

ADVANCED BLEED CONTROLLER

DATA SHEET

 

Digital Conductivity/TDS Meter and controller.

Maintain cycles of concentration of tower water by continuously monitoring the Tower water conductivity.

Bleed control: Once the programmable Setpoint value is reached, an output is activated which operates a

solenoid valve to bleed Tower water.

Inhibitor Dosing. Programmable output, operate on water make-up(water meter), bleed time or via a

programmable timer

Digital LCD display for easy set-up and monitoring – displays measured Conductivity (uS/TDS) the uS/TDS

setpoint and the measured temperature of the cooling tower water

Conductivity range 0 - 10 000µS, resolution is in 1µS increments

Failsafe High, Low TDS/Conductivity and Bleed Timer  alarms

Electronic 2 point calibration via keypad(Zero and Slope)

 

Ordering Options:

Data logging and real time clock calendar

Remote connectivity via cellular engine

4-20mA and BMS retransmission of TDS/Conductivity, Bleed and Inhibitor Outputs, Alarm and mains power

 

BLEED CONTROLLER WITH INHIBITOR DOSE

DATA SHEET

Complete water treatment solution: TDS bleed-off control, programmable inhibitor dosing proportional to

make-up/bleed or timer based, 2 x biocides via 10 x 28-day timers programs complete with bleed lock-out and pre-bleed interlock.

Bleed Control - via solenoid valve

Inhibitor Dosing. Programmable output, operate on water make-up(water meter), bleed time or via a

programmable timer

Dual Biocide Dosing for system disinfection (via 10 x 28-day timer programs).

Pre-bleed & Bleed Lock-out functions.

Condenser pump override facility during biocide dosing which activates the condenser pump during and

after biocide dosing even when the tower is off.

Easy to setup via an advanced menu system.

High, Low TDS/Conductivity, Bleed Timer and no-flow alarms.

Automatic Temperature compensation.

Weatherproof controller enclosure.

 

Ordering Options:

Data logging and real time clock calendar

Remote connectivity via cellular engine

BMS retransmission of TDS/Conductivity, Alarms, Bleed, Inhibitor, 2 x Biocide Outputs and mains healthy outputs through 4-20mA and BMS retransmission

BLEED CONTROLLER WITH INHIBITOR & BIOCIDE TIMERS

DATA SHEET

Digital Conductivity/TDS Meter and controller.

Din Rail mount enclosure.

Maintain cycles of concentration of tower water by continuously monitoring the Tower water conductivity.

Bleed control: Once the programmable Set point value is reached, an output is activated which operates a

solenoid valve to bleed the Tower water in order to maintain Setpoint.

Digital LCD display for easy set-up and monitoring – displays measured Conductivity (uS/TDS) as well as uS/

TDS Set point

Conductivity range 0 - 10 000µS, resolution is in 1µS increments

Electronic 2 point calibration via keypad(Zero and Slope)

DIN RAIL MOUNT BLEED CONTROLLER

DATA SHEET

 Complete water treatment solution: TDS bleed-off control, programmable inhibitor dosing proportional to

make-up/bleed or timer based, 2 x biocides via 10 x 28-day timers programs complete with bleed lock-out and pre-bleed interlock, pH and ORP control and Dispersant dosing control all in one package.

Temperature compensated Bleed Control - via solenoid valve.

Inhibitor Dosing. Programmable output, operate on water make-up(water meter), bleed time or via a

programmable timer

Dual Biocide Dosing for system disinfection (via 10 x 28-day timer programs). Pre-bleed & Bleed Lock-out

Dispersant Dosing. Programmable output, operate on water make-up(water meter), bleed time or via a

programmable timer.

Condenser pump override facility during biocide dosing with delay-off timer.

Programmable alarms on all parameters.

Data logging and real time clock calendar

Programmable Flow switch input, linked to all outputs

Weatherproof IP65 enclosure.

4 Line Dot Matrix LCD Display which displays all analog parameters and system notifications

 

Ordering Options:

GSM Modem for Internet access to all parameters including SMS’s, E-mails, remote setup and graphing of all

parameters

Monitoring of up to 6 x Tank level inputs for water treatment chemicals

Isolated 4-20mA outputs for Conductivity, Temperature, pH & ORP plus logic signals for status of Power,

Alarm, Flow, Bleed & Pump Control Outputs

MULTI PARAMETER CONTROLLER

BLEED, BIOCIDE, ORP pH, & INTERNET

DATA SHEET

Isolated 4-20mA output – tracks Conductivity/TDS

Measurement range 0 - 5000uS

Uses standard conductivity probe

Two point pushbutton calibration feature, Zero and Span

Supplied with compression fittings

Option of 24V AC/DC supply

Weatherproof enclosure

4-20 mA CONDUCTIVITY TRANSMITTER

DATA SHEET

Automatic TDS correction on steaming boilers to maintain a constant TDS level

Measures and displays boiler water conductivity

Four timers to control TDS – sample time, idle time, blow-down time and blow-down wait time

Digital LCD display for easy set-up and monitoring – displays measured TDS as well as TDS Setpoint

Simple pushbutton menu-driven programming

Blow-down period or idle period starts after every sample depending on conductivity level

Sample time, Blowdown time & Idle period independently programmable

Failsafe High & low TDS alarm

Weatherproof enclosure

 

Ordering Options:

DCON-P10S conductivity probe

Data logging and real time clock calendar

Remote connectivity via cellular engine

4-20mA and BMS retransmission

Complete kit ie. controller & steam rated manifold components are available as ordering options

BOILER TDS CONTROLLER

DATA SHEET

Weatherproof Enclosure

Conductivity range 0.1 - 999.9 µS

Monitors Condensate for contamination and raises an Alarm and/or switches On an output should the

condensate quality drops below a programmed level(conductivity exceeds programmable Setpoint)

Backlight LCD display displays measured µS, condensate temperature and Setpoint

Automatic Temperature compensation

Electronic 2 point calibration via keypad

High & low Conductivity alarms

 

Ordering Options:

Data logging and real time clock calendar

Remote connectivity via cellular engine

4-20mA and BMS retransmission