DATA SHEET
Digital Conductivity/TDS Meter and controller.
Maintain cycles of concentration of tower water by continuously monitoring the Tower water conductivity.
Bleed control: Once the programmable Set point value is reached, an output is activated which operates a solenoid valve to bleed the Tower water in order to maintain Setpoint.
Digital LCD display for easy set-up and monitoring – displays measured Conductivity (uS/TDS) as well as uS/TDS Set point
Conductivity range 0 - 10 000µS, resolution is in 1µS increments
Electronic 2 point calibration via keypad(Zero and Slope)
BASIC BLEED CONTROLLER
DATA SHEET
Digital Conductivity/TDS Meter and controller.
Maintain cycles of concentration of tower water by continuously monitoring the Tower water’s conductivity.
Bleed control: Once the programmable Setpoint value is reached, an output is activated which operates a solenoid valve to bleed Tower water.
Digital LCD display for easy set-up and monitoring – displays measured Conductivity (uS/TDS) the uS/TDS Setpoint and the measured temperature of the cooling tower water
Conductivity range 0 - 10 000µS, resolution is in 1µS increments
Failsafe High, Low TDS/Conductivity and Bleed Timer alarms
Electronic 2 point calibration via keypad(Zero and Slope)
Ordering Options:
Data logging and real time clock calendar
Remote connectivity via cellular engine
4-20mA and BMS retransmission
ADVANCED BLEED CONTROLLER
DATA SHEET
Digital Conductivity/TDS Meter and controller.
Maintain cycles of concentration of tower water by continuously monitoring the Tower water conductivity.
Bleed control: Once the programmable Setpoint value is reached, an output is activated which operates a
solenoid valve to bleed Tower water.
Inhibitor Dosing. Programmable output, operate on water make-up(water meter), bleed time or via a
programmable timer
Digital LCD display for easy set-up and monitoring – displays measured Conductivity (uS/TDS) the uS/TDS
setpoint and the measured temperature of the cooling tower water
Conductivity range 0 - 10 000µS, resolution is in 1µS increments
Failsafe High, Low TDS/Conductivity and Bleed Timer alarms
Electronic 2 point calibration via keypad(Zero and Slope)
Ordering Options:
Data logging and real time clock calendar
Remote connectivity via cellular engine
4-20mA and BMS retransmission of TDS/Conductivity, Bleed and Inhibitor Outputs, Alarm and mains power
BLEED CONTROLLER WITH INHIBITOR DOSE
DATA SHEET
Complete water treatment solution: TDS bleed-off control, programmable inhibitor dosing proportional to
make-up/bleed or timer based, 2 x biocides via 10 x 28-day timers programs complete with bleed lock-out and pre-bleed interlock.
Bleed Control - via solenoid valve
Inhibitor Dosing. Programmable output, operate on water make-up(water meter), bleed time or via a
programmable timer
Dual Biocide Dosing for system disinfection (via 10 x 28-day timer programs).
Pre-bleed & Bleed Lock-out functions.
Condenser pump override facility during biocide dosing which activates the condenser pump during and
after biocide dosing even when the tower is off.
Easy to setup via an advanced menu system.
High, Low TDS/Conductivity, Bleed Timer and no-flow alarms.
Automatic Temperature compensation.
Weatherproof controller enclosure.
Ordering Options:
Data logging and real time clock calendar
Remote connectivity via cellular engine
BMS retransmission of TDS/Conductivity, Alarms, Bleed, Inhibitor, 2 x Biocide Outputs and mains healthy outputs through 4-20mA and BMS retransmission
BLEED CONTROLLER WITH INHIBITOR & BIOCIDE TIMERS
DATA SHEET
Digital Conductivity/TDS Meter and controller.
Din Rail mount enclosure.
Maintain cycles of concentration of tower water by continuously monitoring the Tower water conductivity.
Bleed control: Once the programmable Set point value is reached, an output is activated which operates a
solenoid valve to bleed the Tower water in order to maintain Setpoint.
Digital LCD display for easy set-up and monitoring – displays measured Conductivity (uS/TDS) as well as uS/
TDS Set point
Conductivity range 0 - 10 000µS, resolution is in 1µS increments
Electronic 2 point calibration via keypad(Zero and Slope)
DIN RAIL MOUNT BLEED CONTROLLER
DATA SHEET
Complete water treatment solution: TDS bleed-off control, programmable inhibitor dosing proportional to
make-up/bleed or timer based, 2 x biocides via 10 x 28-day timers programs complete with bleed lock-out and pre-bleed interlock, pH and ORP control and Dispersant dosing control all in one package.
Temperature compensated Bleed Control - via solenoid valve.
Inhibitor Dosing. Programmable output, operate on water make-up(water meter), bleed time or via a
programmable timer
Dual Biocide Dosing for system disinfection (via 10 x 28-day timer programs). Pre-bleed & Bleed Lock-out
Dispersant Dosing. Programmable output, operate on water make-up(water meter), bleed time or via a
programmable timer.
Condenser pump override facility during biocide dosing with delay-off timer.
Programmable alarms on all parameters.
Data logging and real time clock calendar
Programmable Flow switch input, linked to all outputs
Weatherproof IP65 enclosure.
4 Line Dot Matrix LCD Display which displays all analog parameters and system notifications
Ordering Options:
GSM Modem for Internet access to all parameters including SMS’s, E-mails, remote setup and graphing of all
parameters
Monitoring of up to 6 x Tank level inputs for water treatment chemicals
Isolated 4-20mA outputs for Conductivity, Temperature, pH & ORP plus logic signals for status of Power,
Alarm, Flow, Bleed & Pump Control Outputs
MULTI PARAMETER CONTROLLER
BLEED, BIOCIDE, ORP pH, & INTERNET
DATA SHEET
Isolated 4-20mA output – tracks Conductivity/TDS
Measurement range 0 - 5000uS
Uses standard conductivity probe
Two point pushbutton calibration feature, Zero and Span
Supplied with compression fittings
Option of 24V AC/DC supply
Weatherproof enclosure
4-20 mA CONDUCTIVITY TRANSMITTER
DATA SHEET
Automatic TDS correction on steaming boilers to maintain a constant TDS level
Measures and displays boiler water conductivity
Four timers to control TDS – sample time, idle time, blow-down time and blow-down wait time
Digital LCD display for easy set-up and monitoring – displays measured TDS as well as TDS Setpoint
Simple pushbutton menu-driven programming
Blow-down period or idle period starts after every sample depending on conductivity level
Sample time, Blowdown time & Idle period independently programmable
Failsafe High & low TDS alarm
Weatherproof enclosure
Ordering Options:
DCON-P10S conductivity probe
Data logging and real time clock calendar
Remote connectivity via cellular engine
4-20mA and BMS retransmission
Complete kit ie. controller & steam rated manifold components are available as ordering options
BOILER TDS CONTROLLER
DATA SHEET
Weatherproof Enclosure
Conductivity range 0.1 - 999.9 µS
Monitors Condensate for contamination and raises an Alarm and/or switches On an output should the
condensate quality drops below a programmed level(conductivity exceeds programmable Setpoint)
Backlight LCD display displays measured µS, condensate temperature and Setpoint
Automatic Temperature compensation
Electronic 2 point calibration via keypad
High & low Conductivity alarms
Ordering Options:
Data logging and real time clock calendar
Remote connectivity via cellular engine
4-20mA and BMS retransmission
CONDENSATE MONITOR